Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Exp Biol Med (Maywood) ; 248(22): 2083-2094, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38059475

RESUMO

Leprosy is a neglected chronic infectious disease caused by obligate intracellular bacilli, Mycobacterium leprae and Mycobacterium lepromatosis. Despite multidrug therapy (MDT) success, leprosy accounts for more than 200,000 new cases yearly. Leprosy diagnosis remains based on the dermato-neurologic examination, but histopathology of skin biopsy and bacilloscopy of intradermal scraping are subsidiary diagnostic tests that require expertise and laboratory infrastructure. This minireview summarizes the state of the art of serologic tests to aid leprosy diagnosis, highlighting enzyme-linked immunosorbent assay (ELISA) and point-of-care tests (POCT) biotechnologies. Also, the impact of the postgenomic era on the description of new recombinantly expressed M. leprae-specific protein antigens, such as leprosy Infectious Disease Research Institute (IDRI) diagnostic (LID)-1 is summarized. Highly specific and sensitive molecular techniques to detect M. leprae DNA as the quantitative polymerase chain reaction (qPCR) and the loop-mediated isothermal amplification (LAMP) are briefly reviewed. Serology studies using phenolic glycolipid-I (PGL-I) semi-synthetic antigens, LID-1 fusion antigen, and the single fusion complex natural disaccharide-octyl (NDO)-LID show high sensitivity in multibacillary (MB) patients. However, serology is not applicable to paucibacillary patients, as they have weak humoral response and robust cell-mediated response, requiring tests for cellular biomarkers. Unlike ELISA-based tests, leprosy-specific POCT based on semi-synthetic PGL-I antigens and NDO-LID 1 antigen is easy to perform, cheaper, equipment-free, and can contribute to early diagnosis avoiding permanent incapacities and helping to interrupt M. leprae transmission. Besides its use to help diagnosis of household contacts or at-risk populations in endemic areas, potential applications of leprosy serology include monitoring MDT efficacy, identification of recent infection, especially in young children, as surrogate markers of disease progression to orient adult chemoprophylaxis and as a predictor of type 2 leprosy reactions. Advances in molecular biology techniques have reduced the complexity and execution time of qPCR confirming its utility to help diagnosis while leprosy-specific LAMP holds promise as an adjunct test to detect M. leprae DNA.


Assuntos
Doenças Transmissíveis , Hanseníase , Adulto , Criança , Humanos , Pré-Escolar , Quimioterapia Combinada , Hansenostáticos , Antígenos de Bactérias , Anticorpos Antibacterianos , Hanseníase/diagnóstico , Mycobacterium leprae/genética , Glicolipídeos , DNA
2.
Anal Methods ; 16(1): 74-82, 2023 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-38073521

RESUMO

This study presents the development of a polyester microplate for detecting the S-protein of the SARS-CoV-2 virus in saliva and nasopharyngeal swab samples using direct enzyme-linked immunosorbent assay (ELISA) technology. The polyester microplate was designed to contain 96 zones with a 3 mm diameter each, and a volume of 2-3 µL. The experimental conditions including reagent concentration and reaction time were optimized. The microplate image was digitized and analyzed using graphical software. The linear range obtained between protein S concentrations and pixel intensity was 0-10 µg mL-1, with a correlation coefficient of 0.99 and a limit of detection of 0.44 µg mL-1. The developed methodology showed satisfactory intraplate and interplate repeatability with RSD values lower than 7.8%. The results achieved through immunoassay performed on polyester microplates were consistent with those of the RT-PCR method and showed a sensitivity of 100% and 90% and specificity of 85.71% and 100% for saliva and nasopharyngeal samples, respectively. The proposed direct immunoassay on polyester microplates emerges as an alternative to conventional immunoassays performed on commercial polystyrene plates, given the low cost of the device, low consumption of samples and reagents, lower waste generation, and shorter analysis time. Moreover, the immunoassay has shown great potential for diagnosing COVID-19 with precision and accuracy.


Assuntos
COVID-19 , Saliva , Humanos , Glicoproteína da Espícula de Coronavírus , Colorimetria , COVID-19/diagnóstico , Imunoensaio
3.
Braz J Microbiol ; 54(4): 2893-2901, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37930615

RESUMO

The gold standard for diagnosing COVID-19 in the acute phase is RT-qPCR. However, this molecular technique can yield false-negative results when nasopharyngeal swab collection is not conducted during viremia. To mitigate this challenge, the enzyme-linked immunosorbent assay (ELISA) identifies anti-SARS-CoV-2 IgM antibodies in the initial weeks after symptom onset, facilitating early COVID-19 diagnosis. This study introduces a novel and highly specific IgM antibody capture ELISA (MAC-ELISA), which utilizes biotinylated recombinant SARS-CoV-2 nucleocapsid (N) antigen produced in plants. Our biotinylated approach streamlines the procedure by eliminating the requirement for an anti-N-conjugated antibody, circumventing the need for peroxidase-labeled antigens, and preventing cross-reactivity with IgM autoantibodies such as rheumatoid factor. Performance evaluation of the assay involved assessing sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy using 682 RT-qPCR-positive samples, categorized by weeks relative to symptoms onset. Negative controls included 205 pre-pandemic serum samples and 46 serum samples from patients diagnosed with other diseases. Based on a cut-off of 0.087 and ROC curve analysis, the highest sensitivity of 81.2% was observed in the 8-14 days post-symptom (dps) group (2nd week), followed by sensitivities of 73.8% and 68.37% for the 1-7 dps (1st week) and 15-21 dps groups (3rd week), respectively. Specificity was consistently 100% across all groups. This newly developed biotinylated N-MAC-ELISA offers a more streamlined and cost-effective alternative to molecular diagnostics. It enables simultaneous testing of multiple samples and effectively identifies individuals with false-negative results.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , SARS-CoV-2 , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina M , Anticorpos Antivirais , Nucleocapsídeo , Sensibilidade e Especificidade
4.
J Virol Methods ; 315: 114710, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36914098

RESUMO

A plant-based heterologous expression system is an attractive option for recombinant protein production because it is based on a eukaryotic system of high feasibility, and low biological risks. Frequently, binary vector systems are used for transient gene-expression in plants. However, plant virus vector-based systems offer advantages for higher protein yields due to their self-replicating machinery. In the present study, we show an efficient protocol using a plant virus vector based on a tobravirus, pepper ringspot virus, that was employed for transient expression of severe acute respiratory syndrome coronavirus 2 partial gene fragments of the spike (named S1-N) and the nucleocapsid (named N) proteins in Nicotiana benthamiana plants. Purified proteins yield of 40-60 µg/g of fresh leaves were obtained. Both proteins, S1-N and N, showed high and specific reactivities against convalescent patients' sera by the enzyme-linked immunosorbent assay format. The advantages and critical points in using this plant virus vector are discussed.


Assuntos
COVID-19 , Vírus de RNA , Humanos , SARS-CoV-2/genética , Proteínas Recombinantes , Ensaio de Imunoadsorção Enzimática , Glicoproteína da Espícula de Coronavírus/genética
5.
J Food Sci Technol ; 60(1): 123-131, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36618043

RESUMO

Listeria monocytogenes is a food-borne bacterium that causes listeriosis upon the ingestion of contaminated food. Traditional methods to detect L. monocytogenes require pre-enrichment broths to increase its concentration. To improve the screening of contaminated food and prevent listeriosis outbreaks, rapid, specific and sensitive assays are needed to detect L. monocytogenes. This study developed a prototype lateral flow immunochromatographic assay (LFIA) employing antibodies against L. monocytogenes Internalin A (InlA) and Internalin B (InlB) proteins, that are involved in non-phagocytic cell invasion. The following antibodies were used to capture L. monocytogenes antigenic targets: mouse anti-Internalin A monoclonal antibody (MAb-2D12) conjugated to colloidal gold nanoparticles and a mouse anti-Internalin B polyclonal antibody. This test was able to detect pure L. monocytogenes from culture with a limit of detection (LOD) ranging from 5.9 × 103 to 1.5 × 104 CFU/mL. In milk artificially contaminated with L. monocytogenes, the LOD was 1 × 105 CFU/mL. This prototype test discriminated L. monocytogenes from other bacterial species (Listeria innocua, Enterobacter cloacae, Bacillus cereus). Results indicate that this LFIA developed using antibodies against L. monocytogenes InlA and InlB proteins is a sensitive and specific tool that can be potentially useful to rapidly detect L. monocytogenes in contaminated food. Supplementary Information: The online version contains supplementary material available at 10.1007/s13197-022-05597-9.

6.
Anal Bioanal Chem ; 413(16): 4161-4180, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34041576

RESUMO

Listeria monocytogenes is an invasive opportunistic foodborne pathogen and its routine surveillance is critical for protecting the food supply and public health. The traditional detection methods are time-consuming and require trained personnel. Lateral flow immunoassay (LFIA), on the other hand, is an easy-to-perform, rapid point-of-care test and has been widely used as an inexpensive surveillance tool. In recent times, nucleic acid-based lateral flow immunoassays (NALFIA) are also developed to improve sensitivity and specificity. A significant improvement in lateral flow-based assays has been reported in recent years, especially the ligands (antibodies, nucleic acids, aptamers, bacteriophage), labeling molecules, and overall assay configurations to improve detection sensitivity, specificity, and automated interpretation of results. In most commercial applications, LFIA has been used with enriched food/environmental samples to ensure detection of live cells thus prolonging the assay time to 24-48 h; however, with the recent improvement in LFIA sensitivity, results can be obtained in less than 8 h with shortened and improved enrichment practices. Incorporation of surface-enhanced Raman spectroscopy and/or immunomagnetic separation could significantly improve LFIA sensitivity for near-real-time point-of-care detection of L. monocytogenes for food safety and public health applications.


Assuntos
Imunoensaio/métodos , Listeria monocytogenes/isolamento & purificação , Listeriose/microbiologia , Animais , Anticorpos Imobilizados/química , Microbiologia de Alimentos , Humanos , Imunoensaio/instrumentação , Listeriose/diagnóstico , Ácidos Nucleicos/química , Sistemas Automatizados de Assistência Junto ao Leito
7.
Crit Rev Microbiol ; 47(5): 647-666, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33896354

RESUMO

Listeria monocytogenes is one of the most invasive foodborne pathogens and is responsible for numerous outbreaks worldwide. Most of the methods to detect this bacterium in food require selective enrichment using traditional bacterial culture techniques that can be time-consuming and labour-intensive. Moreover, molecular methods are expensive and need specific technical knowledge. In contrast, immunological approaches are faster, simpler, and user-friendly alternatives and have been developed for the detection of L. monocytogenes in food, environmental, and clinical samples. These techniques are dependent on the constitutive expression of L. monocytogenes antigens and the specificity of the antibodies used. Here, updated knowledge on pathogenesis and the key immunogenic virulence determinants of L. monocytogenes that are used for the generation of monoclonal and polyclonal antibodies for the serological assay development are summarised. In addition, immunological approaches based on enzyme-linked immunosorbent assay, immunofluorescence, lateral flow immunochromatographic assays, and immunosensors with relevant improvements are highlighted. Though the sensitivity and specificity of the assays were improved significantly, methods still face many challenges that require further validation before use.


Assuntos
Listeria monocytogenes/isolamento & purificação , Listeria monocytogenes/patogenicidade , Listeriose/microbiologia , Fatores de Virulência/análise , Fatores de Virulência/imunologia , Animais , Anticorpos Antibacterianos/imunologia , Antígenos de Bactérias/análise , Antígenos de Bactérias/imunologia , Técnicas Biossensoriais , Microbiologia de Alimentos , Humanos , Imunidade Inata , Listeria monocytogenes/crescimento & desenvolvimento , Listeria monocytogenes/imunologia , Listeriose/diagnóstico , Listeriose/imunologia , Virulência , Fatores de Virulência/metabolismo
8.
Mol Biol Rep ; 47(10): 7333-7340, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32997310

RESUMO

Dengue virus and Zika virus are arthropod-borne flaviviruses that cause millions of infections worldwide. The co-circulation of both viruses makes serological diagnosis difficult as they share high amino acid similarities in viral proteins. Antigens are one of the key reagents in the differential diagnosis of these viruses through the detection of IgG antibodies in serological assays during the convalescent-phase of infections. Here, we report the expression of Dengue virus (DENV) and Zika virus (ZIKV) antigens containing non-conserved and immunodominant amino acid sequences using the baculovirus expression vector system in insect cells. We designed DENV and ZIKV antigens based on the domain III of the E protein (EDIII) after analyzing previously reported epitopes and by multiple alignment of the most important flaviviruses. The ZIKV and DENV multi-epitope genes were designed as tandem repeats or impaired repeats separated by tetra- or hexa-glycine linkers. The biochemical analyses revealed adequate expression of the antigens. Then, the obtained multi-epitope antigens were semi-purified in a sucrose gradient and tested using patients' sera collected during the convalescent-phase that were previously diagnosed positive for anti-DENV and -ZIKV IgG antibodies. The optimal serum dilution was 1:200, and the mean absorbance values in the preliminary tests show that multi-epitope antigens have been recognized by human sera. The production of both antigens using the multi-epitope strategy in the eukaryotic system and based on the EDIII regions provide a proof of concept for the use of antigens in the differentiation between DENV and ZIKV.


Assuntos
Antígenos Virais , Vírus da Dengue/genética , Epitopos , Expressão Gênica , Proteínas Recombinantes de Fusão , Proteínas do Envelope Viral , Zika virus/genética , Animais , Antígenos Virais/biossíntese , Antígenos Virais/genética , Baculoviridae/genética , Baculoviridae/metabolismo , Linhagem Celular , Epitopos/biossíntese , Epitopos/genética , Mariposas , Proteínas Recombinantes de Fusão/biossíntese , Proteínas Recombinantes de Fusão/genética , Proteínas do Envelope Viral/biossíntese , Proteínas do Envelope Viral/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...